Ftir analysis laboratories in Chelmsford, MA 2021? Conclusion: Based on the analytical report, the client was able to demonstrate that the particles were consistent with a common aspirin tablet. When the end customer was approached with this report, they remembered that their spouse had taken an aspirin earlier that morning, and had likely used the bottle of water in question to do so. Based on this, the customer was happy, the manufacturing client was satisfied, and the sample was maintained – undestroyed should someone need to examine the sample again or do any more esoteric testing. For an affordable price, the client was able to get piece of mind, and gather information from a very wide range of testing methods quickly and accurately.
SEM is a powerful surface microscopy method which allows for high resolution images to be obtained on a wide range of samples. A focused beam of electrons sweeps across a sample surface and an image is created from the scattered electrons. The electron beam allows for the accurate imaging of features below the resolution limit of visible light. The acquired pictures retain good depth of field, resulting in excellent three-dimensional images. Variations in beam parameters can be made in order to highlight variations in density in the target sample, show extremely fine surface features, and illustrate texture in sample surface coatings. MicroVision Labs has multiple fully-operational SEMs, Bruker X-Flash EDS detectors and mapping technology, backscatter electron (BSE) imaging, and large chamber capabilities. These provide a full suite of microscopy services for all of your analytical needs.
Do you give lab tours? Yes, we routinely give lab tours to our clients and potential clients. Please call and we would be happy to schedule a tour for you and your co-workers. Do you have other locations around the country? We do work for companies all across the United States, with one laboratory which is located in Chelmsford, Massachusetts. Did MicroVision Labs ever operate under a different company name? No, we have always been MicroVision Laboratories, Inc. Our founder, John Knowles, used to work for another laboratory that underwent several name changes (Eastern Analytical Laboratories, Industrial Environmental Analysts, American Environmental Network, Severn Trent Laboratories, and EMLab P&K Billeria) and was located nearby in Billerica. When that laboratory was closed in 2008, John hired a few of the remaining analysts and acquired its equipment, client list and phone number. Discover a few more info on https://microvisionlabs.com/services/. We are proud to announce that MicroVision Labs is now accredited to the ISO/IEC 17025:2017 standard. This represents over a year of diligent effort from all of our staff to verify and validate our in house SOP’s and transform our quality management system to one that is compliant to this international standard. This certification requires that accredited labs demonstrate that they are competent and can produce technically valid data and results unlike other certifications such as ISO 9001:2015. This represents an obvious value to our clients.
A client responsible for maintaining the facilities in a public school district called with concerns of a possible mold problem. Areas with high foot traffic, especially those where students tracked water in, were showing dark black spots in the floor tiles. Aggressive cleaning and buffing of the floor would remove the problem for a while, but after several few weeks, the problem resurfaced. The facilities management staff was convinced it was mold related, but sending samples, swabs, and air grabs to a mold lab for culturing showed no sign of fungal structures on the tiles.
A device manufacturer had a product that involved a few different boards with varying components. There were circumstances that caused the need for a change in manufacturers of one of the boards. Due to this change, the device production at this facility would be shut down until the boards from this new vendor were validated. The Quality Control department required that an inspection of the solder joints of some of the components on the board be analyzed in order to determine whether this new board manufacturer met their specifications. If the desired specifications were met and no issues were found during the inspection of the joints then production of the devices could resume. Find more info at https://microvisionlabs.com/.